• 中国科学论文统计源期刊
  • 中国科技核心期刊
  • 美国化学文摘(CA)来源期刊
  • 日本科学技术振兴机构数据库(JST)

临床输血与检验 ›› 2019, Vol. 21 ›› Issue (1): 24-27.DOI: 10.3969/j.issn.1671-2587.2019.01.008

• 临床输血 • 上一篇    下一篇

不同方式放置白膜制备浓缩血小板质量指标比较*

刁荣华, 王泽蓉, 王世春, 黄红梅, 赵树铭, 范娅涵   

  1. 400038 重庆,陆军军医大学第一附属医院输血科, 中国人民解放军重庆血站
  • 收稿日期:2018-09-03 出版日期:2019-02-20 发布日期:2019-01-28
  • 通讯作者: 范娅涵,女,副主任医师,主要从事血液安全与临床输血研究,(E-mail)yahanfan@139.com。
  • 作者简介:刁荣华(1980-),女,重庆人,学士,主管护师,本科,主要从事血液采集及制备工作,(E-mail)drh_sxk2007@163.com。
  • 基金资助:
    本课题受国家自然科学基金项目(No.81570167,81700180); 院管课题 (No.SWH2016LHZH-01)资助

Study on the Qualities of Two Kinds Buffy-Coat-Collected Platelet Concentrates

DIAO Rong-hua, WANG Ze-rong, WANG Shi-chun, et al   

  1. Department of Blood Transfusion,Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038
  • Received:2018-09-03 Online:2019-02-20 Published:2019-01-28

摘要: 目的 探讨全血分离白膜静置2 h后,血小板恒温保存箱振荡过夜保存白膜袋及静置室温过夜保存白膜袋,对制备浓缩血小板回收率及血小板质量指标的影响。方法 对124份400 mL新鲜全血进行容量检测和血常规计数,随机选取其中53份当日分离白膜静置2 h后置血小板恒温保存箱振荡过夜保存为实验组,剩余71份当日分离白膜后静置室温过夜保存为对照组,两组白膜于次日制备浓缩血小板。然后对两组浓缩血小板进行pH、葡萄糖、血小板聚集率及血小板低渗休克反应相对变化率(HSR)的测定。结果 白膜振荡过夜保存和静止过夜保存后制备的浓缩血小板计数分别为(7.23±2.21)×1010和(7.17±2.08)×1010,实验组高于对照组,差异无统计学意义。但是血小板回收率则是实验组为68.69%±19.21%,高于对照组血小板回收率62.07%±11.37%,差异有统计学意义。实验组和对照组制备的浓缩血小板pH值分别为7.23±0.08和7.12±0.14,GLU( mmol /L)分别为20.57±1.26和19.32±1.41,血小板聚集率分别为92.65%±3.02%和88.82%±3.43%,差异均无统计学意义。实验组浓缩血小板HSR为81.50%±8.57%,明显高于对照组浓缩血小板74.30%±11.55%,差异有统计学意义。结论 两种方式放置白膜袋所制备的浓缩血小板,检测指标均符合国家质量标准,但血小板回收率和体外功能检测指标HSR显示白膜静置后振荡过夜方式制备的浓缩血小板可能更具有优势。

关键词: 白膜法, 振荡, 静置, 浓缩血小板

Abstract: Objective This study was aimed to compare the difference of qualities between two kinds Buffy-Coat-Collected Platelet Concentrates. Methods 400ml of whole blood were harvested from each of 124 healthy donors and then were separated and prepared to obtain the platelets through buffy coat method. 124 buffy coats were divided into 2 groups randomly, 53 buffy coats in experiment group were agitated overnight after standing 2 hours in platelet agitating container, while 71 buffy coats in control group were stewing overnight at room temperature. pH, GLU, HSR, platelet aggregation rate were observed in all platelet concentrates. Results There was no difference in platelet counts, pH and platelet aggregation rate between the two groups (P>0.05).However, compared with the control group, platelets collected from agitated buffy coats had higher ability to hypotonic shock response and a higher rate of platelet recovery (P<0.05). Conclusion Two kinds of buffy-coat-collected platelet concentrates meet the requirement of relevant standards. Platelet concentrates from agitated buffy coats maybe have more advantages over those from stewing buffy coats in HSR and platelet recovery rate.

Key words: Buffy coat, Oscillation, Statics, Platelet concentrates

中图分类号: