• 中国科学论文统计源期刊
  • 中国科技核心期刊
  • 美国化学文摘(CA)来源期刊
  • 日本科学技术振兴机构数据库(JST)

临床输血与检验 ›› 2016, Vol. 18 ›› Issue (3): 240-242.DOI: 10.3969/j.issn.1671-2587.2016.03.013

• 临床输血研究 • 上一篇    下一篇

73 727例拟输血患者血清HIV抗体化学发光免疫检测与分析*

黄琬婷, 何露, 陈廷寅, 曹微微, 舒象武, 肖超奇, 李碧娟, 李宁   

  1. 410008 长沙,中南大学湘雅医院输血科(黄琬婷,何露,曹微微,舒象武,肖超奇,李碧娟,李宁); 信息科(陈廷寅)
  • 收稿日期:2015-11-28 出版日期:2016-06-20 发布日期:2016-09-21
  • 通讯作者: 李宁(1970-),男,副教授,博士,研究生导师,主要从事输血感染与免疫血液学研究,(Tel)0731-89753109(E-mail)nxli1970@126.com。
  • 作者简介:黄琬婷(1990-),女,吉林安图人,在读硕士研究生,主要从事临床检验诊断学工作,(Tel)15367892755(E-mail)stop-5@126.com。
  • 基金资助:
    *本课题受中南大学中央高校基本科研业务费专项资金(No.2015zzts304)资助

The Analysis and Detection of anti-HIV by Chemiluminescence Assay in 73 727 Blood Recipients before Transfusion

HUANG Wan-ting, HE Lu, CHEN Ting-yin, et al   

  1. Department of Blood Transfusion of Xiangya Hospital,Central South University, Changsha,410008
  • Received:2015-11-28 Online:2016-06-20 Published:2016-09-21

摘要: 目的评估化学发光免疫试验(CLIA)法检测人类免疫缺陷病毒(HIV)抗体的特异性,并对HIV抗体阳性患者进行分析。方法采用CLIA试验对本院住院和门诊73727例拟输血患者血清标本进行HIV抗体检测,阳性标本用免疫印迹试验(WB)确认。结果CLIA 法检测发现阳性140例,WB法阳性确认110例,拟输血患者中HIV感染率为0.15%;HIV感染患者以21~60岁年龄段为主,男性感染率为0.20%,女性为0.09%,男女病毒感染率的差异有统计学意义(P<0.05);CLIA 法S/CO值小于10的阳性标本,经WB法HIV阳性确认率为0;S/CO值大于50的标本,WB法阳性确认率为100%;比较 1<S/CO≤10, 10<S/CO≤50 和S/CO>50三组,WB法获得的阳性率的差异均有统计学意义。结论住院和门诊拟输血患者有较高的HIV感染率,CLIA 法灵敏度虽高,但低S/CO值的标本HIV抗体检测特异性较低。

关键词: 人类免疫缺陷病毒, 化学发光免疫试验, 免疫印迹试验

Abstract: ObjectiveTo evaluate the specificity of chemiluminescence assay (CLIA) in anti-HIV test, and to analyze HIV infection in the patients before blood transfusion. MethodsCLIA was used to detect the anti-HIV in 73727 cases from pre-transfusion patients. The sera with initially positive anti-HIV was then confirmed by Western blotting (WB). ResultsOne hundred and forty f serum samples were anti-HIV positive by CLIA. Among them, 110 were confirmed to be positive by WB assay. Anti-HIV was more prevalent in those aged 20-60 years, and the HIV infection rate of male is much higher than that of female (χ2=15.01,P<0.005). In the samples with S/CO value between 1 and 10, the seroprevalence of anti-HIV was 0%, while in the sample with S/CO value more than 50, the seroprevalence of anti-HIV was 100% tested with WB assay. The anti-HIV positive rate of WB assay showed significant difference among 1<S/CO≤10, 10<S/CO≤50 and S/CO>50 three groups (P<0.005). ConclusionsPart of blood recipients before transfusion have HIV infection. Low S/CO value indicates relatively high false positive HIV infection although CLIA shows high sensitivity.

Key words: Human, immunodeficiency, virus, Chemiluminescence, assay, Western, blot

中图分类号: