摘要: 目的 探索血细胞分离机单采冲红时参数修改对血小板冲红的改善情况。方法 血小板采集过程中发生冲红或提示血小板峰值低时,调整设置单采机采集参数,监测血小板后续采集情况。结果 经过参数修改设置后,26例有冲红风险的血小板采集中18例采集成功,成功率为69.2%,但仍有8例出现冲红。结论 采集参数修改可以部分改善血小板冲红现象,进而提升血小板采集成功率,减少血小板浪费、人力及血小板采集耗材的损耗,降低采集成本。

关键词: 血小板, 冲红, MCS+, 参数修改

Abstract: Objective This study is to explore whether the parameter modification can improve the platelet erythrocyte overflow while the erythrocyte overflow occurs during the operation of the MCS+ Blood cell collector. Method ology:When the erythrocyte overflows or peak of platelet falls during the platelet collection process,the parameters of MCS+ blood cell collector would be modified and the collection of platelets thereafter would be noted. Results 18 of the 26 cases of collection with potential risk of erythrocyte overflow were then collected successfully after the parameters were modified,achieving a success rate of 69.2%; but erythrocyte overflow still occurred in the other 8 cases.Conclusion This study shows that parameter modification can partially reduce risk of erythrocyte overflow then increase the success rate of platelet collection,which can also lower the cost of platelet collection in terms of both labor and supplies.

Key words: Platelet, Erythrocyte overflow, MCS+, Parameter modification